销售热线 400-812-0328  |  微信同号 13798439218  |  WhatsApp +85251628371
欢迎光临本店 请登录  |  免费注册
当前位置: 首页 > 行业资讯 > Common Foam-in-Place Defects: How to Read Bubbles, Collapse, Tackiness and Uneven Density, and What to Check
Common Foam-in-Place Defects: How to Read Bubbles, Collapse, Tackiness and Uneven Density, and What to Check
CosMolar / 2026-11-24

Once foam-in-place has set, the appearance and feel of the block often show whether the formula, material temperature, mixing and packing cadence are right. Reading the symptom before reworking saves material and time over patching blindly. This article covers four common defects: large bubbles or honeycomb holes, local collapse, tacky surfaces, and uneven hardness, describing how each looks, common causes and where to check.

Large bubbles or honeycomb holes

Visible oversized holes inside or on the surface, sometimes honeycomb-like, commonly come from low material temperature, insufficient A/B mixing, moving the product too early during setting, or an A/B ratio off. Check drum and ambient temperature first, confirm mixing is thorough, keep the product still for the 3-5 second setting period, then review ratio and material feed.

Local collapse or sinking foam

One side sinks or thins, or foam around the product is pressed flat. This often means the product was pressed too early, insufficient cushion space was left in the carton, or too little chemical was dosed. Review empty-space allowance and chemical amount; press lightly for 3-5 seconds to set before moving. For heavy products, step up a density grade instead of over-dosing chemical to compensate.

Tacky surface that does not set into a film

A sticky surface that marks when pressed and does not form a continuous film often points to low material temperature, high humidity, incomplete reaction, or A/B chemicals dampened or past shelf life. Check drum sealing and storage, workshop temperature and humidity, and material shelf life; confirm A and B materials have not been mixed or dampened.

Uneven hardness or density

If one carton of foam varies from soft to firm, check A/B ratio, mixing uniformity and drum material feed. The density grade must also match product weight: 6kg/m³ is the general-purpose main grade, with 17kg/m³ and 23kg/m³ for heavy parts and stronger support; do not pack heavy parts with a low-density foam.

Recommended check order

On site, follow: read the visible symptom first, check material temperature, humidity and operation cadence, inspect A/B condition and ratio, then review chemical amount and density grade. When unsure, send CosMolar the sample block and packing conditions; technicians review the foam sample and suggest adjustments.

CosMolar supplies semi-automatic and fully automatic foam machines, A/B foam chemicals, hand foam bags and PE film, with sample calibration and operator training. More troubleshooting points at https://www.cosmolar.com/.

用户评论(共0条评论)

  • 暂时还没有任何用户评论
总计 0 个记录,共 1 页。 第一页 上一页 下一页 最末页
用户名: 匿名用户
E-mail:
评价等级:
评论内容:
验证码: captcha